Program Version:EnergyPlus, Version 23.1.0-87ed9199d4, YMD=2026.07.16 13:48
Tabular Output Report in Format: HTML
Building: Vivienda aislada - Guía de aplicación DB HE 2019. EJEMPLOS (I)
Environment: RUNPERIOD 1 ** E1_peninsula - ESP CTE_DB_HE WMO#=
Simulation Timestamp: 2026-07-16 13:48:06
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Values gathered over 8760.00 hours| Total Energy [kWh] | Energy Per Total Building Area [kWh/m2] | Energy Per Conditioned Building Area [kWh/m2] | |
| Total Site Energy | 10565.83 | 55.03 | 82.55 |
| Net Site Energy | 10565.82 | 55.03 | 82.55 |
| Total Source Energy | 16922.59 | 88.14 | 132.21 |
| Net Source Energy | 16922.59 | 88.14 | 132.21 |
| Site=>Source Conversion Factor | |
| Electricity | 2.368 |
| Natural Gas | 1.195 |
| District Cooling | 1.184 |
| District Heating | 1.299 |
| Steam | 0.250 |
| Gasoline | 0.000 |
| Diesel | 0.000 |
| Coal | 1.084 |
| Fuel Oil No 1 | 1.182 |
| Fuel Oil No 2 | 0.000 |
| Propane | 1.204 |
| Other Fuel 1 | 1.037 |
| Other Fuel 2 | 1.113 |
| Area [m2] | |
| Total Building Area | 192.00 |
| Net Conditioned Building Area | 128.00 |
| Unconditioned Building Area | 64.00 |
| Electricity [kWh] | Natural Gas [kWh] | Gasoline [kWh] | Diesel [kWh] | Coal [kWh] | Fuel Oil No 1 [kWh] | Fuel Oil No 2 [kWh] | Propane [kWh] | Other Fuel 1 [kWh] | Other Fuel 2 [kWh] | District Cooling [kWh] | District Heating [kWh] | Water [m3] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4421.96 | 0.00 | 0.00 | 0.00 |
| Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 1850.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1850.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 60.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2383.08 | 40.87 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 3760.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4421.96 | 0.00 | 2383.08 | 40.87 |
| Subcategory | Electricity [kWh] | Natural Gas [kWh] | Gasoline [kWh] | Diesel [kWh] | Coal [kWh] | Fuel Oil No 1 [kWh] | Fuel Oil No 2 [kWh] | Propane [kWh] | Other Fuel 1 [kWh] | Other Fuel 2 [kWh] | District Cooling [kWh] | District Heating [kWh] | Water [m3] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Boiler | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4421.96 | 0.00 | 0.00 | 0.00 | |
| Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Cooling | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 1 | 1850.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | General | 1850.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 60.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2383.08 | 40.87 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [kWh] | Natural Gas [kWh] | Gasoline [kWh] | Diesel [kWh] | Coal [kWh] | Fuel Oil No 1 [kWh] | Fuel Oil No 2 [kWh] | Propane [kWh] | Other Fuel 1 [kWh] | Other Fuel 2 [kWh] | District Cooling [kWh] | District Heating [kWh] | Water [m3] | |
| Heating | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4421.96 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | GENERAL | 1850.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | GENERAL | 1850.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 60.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2383.08 | 40.87 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [kWh/m2] | Natural Gas Intensity [kWh/m2] | Gasoline Intensity [kWh/m2] | Diesel Intensity [kWh/m2] | Coal Intensity [kWh/m2] | Fuel Oil No 1 Intensity [kWh/m2] | Fuel Oil No 2 Intensity [kWh/m2] | Propane Intensity [kWh/m2] | Other Fuel 1 Intensity [kWh/m2] | Other Fuel 2 Intensity [kWh/m2] | District Cooling Intensity [kWh/m2] | District Heating Intensity [kWh/m2] | Water Intensity [m3/m2] | |
| Lighting | 14.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 0.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.55 | 0.00 | 18.62 | 0.32 |
| Other | 14.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 29.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.55 | 0.00 | 18.62 | 0.32 |
| Electricity Intensity [kWh/m2] | Natural Gas Intensity [kWh/m2] | Gasoline Intensity [kWh/m2] | Diesel Intensity [kWh/m2] | Coal Intensity [kWh/m2] | Fuel Oil No 1 Intensity [kWh/m2] | Fuel Oil No 2 Intensity [kWh/m2] | Propane Intensity [kWh/m2] | Other Fuel 1 Intensity [kWh/m2] | Other Fuel 2 Intensity [kWh/m2] | District Cooling Intensity [kWh/m2] | District Heating Intensity [kWh/m2] | Water Intensity [m3/m2] | |
| Lighting | 9.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 0.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.03 | 0.00 | 12.41 | 0.21 |
| Other | 9.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 19.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.03 | 0.00 | 12.41 | 0.21 |
| Electricity [kWh] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 3760.782 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 3760.782 | 100.00 |
| Total On-Site and Utility Electric Sources | 3760.782 | 100.00 |
| Total Electricity End Uses | 3760.784 | 100.00 |
| Heat [kWh] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | |
| Air to Air Heat Recovery for Cooling | 0.00 | |
| Air to Air Heat Recovery for Heating | 0.00 | |
| High-Temperature Geothermal* | 0.00 | |
| Solar Water Thermal | 0.00 | |
| Solar Air Thermal | 0.00 | |
| Total On-Site Thermal Sources | 0.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 40.87 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 40.87 | 100.00 |
| Total Water End Uses | 40.87 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 1.00 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 1.00 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 233.50 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 5546.50 |
Table of Contents
TopReport: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
General| Value | |
| Program Version and Build | EnergyPlus, Version 23.1.0-87ed9199d4, YMD=2026.07.16 13:48 |
| RunPeriod | RUNPERIOD 1 |
| Weather File | E1_peninsula - ESP CTE_DB_HE WMO#= |
| Latitude [deg] | 40.68 |
| Longitude [deg] | -4.1 |
| Elevation [m] | 667.00 |
| Time Zone | 1.00 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 198.57 | 36.02 | 36.02 | 90.51 | 36.02 |
| Above Ground Wall Area [m2] | 182.57 | 32.02 | 32.02 | 86.51 | 32.02 |
| Window Opening Area [m2] | 32.40 | 8.10 | 9.60 | 12.50 | 2.20 |
| Gross Window-Wall Ratio [%] | 16.32 | 22.49 | 26.65 | 13.81 | 6.11 |
| Above Ground Window-Wall Ratio [%] | 17.75 | 25.29 | 29.98 | 14.45 | 6.87 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 182.57 | 32.02 | 32.02 | 86.51 | 32.02 |
| Above Ground Wall Area [m2] | 182.57 | 32.02 | 32.02 | 86.51 | 32.02 |
| Window Opening Area [m2] | 32.40 | 8.10 | 9.60 | 12.50 | 2.20 |
| Gross Window-Wall Ratio [%] | 17.75 | 25.29 | 29.98 | 14.45 | 6.87 |
| Above Ground Window-Wall Ratio [%] | 17.75 | 25.29 | 29.98 | 14.45 | 6.87 |
| Total | |
| Gross Roof Area [m2] | 90.51 |
| Skylight Area [m2] | 4.00 |
| Skylight-Roof Ratio [%] | 4.42 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| Z01_VIVIENDA | 128.00 | Yes | Yes | 341.52 | 1.00 | 182.57 | 0.00 | 24.60 | 32.40 | 4.4000 | 28.49 | 4.4000 |
| Z02_CAMARA_SANITARIA | 64.00 | No | Yes | 32.00 | 1.00 | 0.00 | 16.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
| Total | 192.00 | 373.52 | 182.57 | 16.00 | 24.60 | 32.40 | 2.9333 | 42.74 | 2.9333 | |||
| Conditioned Total | 128.00 | 341.52 | 182.57 | 0.00 | 24.60 | 32.40 | 4.4000 | 28.49 | 4.4000 | |||
| Unconditioned Total | 64.00 | 32.00 | 0.00 | 16.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | ||||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| Z01_VIVIENDA | 128.00 | Yes | Yes | 1.00 | Z01_VIVIENDA | GENERAL | Z01_VIVIENDA | 4.4000 | 28.49 | 4.4000 | |
| Z02_CAMARA_SANITARIA | 64.00 | No | Yes | 1.00 | Z02_CAMARA_SANITARIA | GENERAL | Z02_CAMARA_SANITARIA | 0.0000 | 0.00 | 0.0000 | |
| Total | 192.00 | 2.9333 | 42.74 | 2.9333 | |||||||
| Conditioned Total | 128.00 | 4.4000 | 28.49 | 4.4000 | |||||||
| Unconditioned Total | 64.00 | 0.0000 | 0.00 | 0.0000 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| GENERAL | 192.00 | 128.00 | 64.00 | 0.00 | 2.9333 | 42.74 | 2.9333 |
| Total | 192.00 | 128.00 | 64.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | District Heating [W] | Water [m3/s] | |
| Time of Peak | 01-JAN-19:30 | - | - | - | - | - | - | - | - | 27-DEC-07:30 | - | 01-JAN-00:30 | 01-JAN-07:30 |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6160.08 | 0.00 | 0.00 | 0.00 |
| Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 563.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 563.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 7.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 302.72 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 1134.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6160.08 | 0.00 | 302.72 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | District Heating [W] | Water [m3/s] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Boiler | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6160.08 | 0.00 | 0.00 | 0.00 | |
| Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Cooling | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 1 | 563.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | General | 563.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Ventilation (simple) | 7.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 302.72 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Values gathered over 8760.00 hours| Source Electricity [kWh] | Source Natural Gas [kWh] | Source Gasoline [kWh] | Source Diesel [kWh] | Source Coal [kWh] | Source Fuel Oil No 1 [kWh] | Source Fuel Oil No 2 [kWh] | Source Propane [kWh] | Source Other Fuel 1 [kWh] | Source Other Fuel 2 [kWh] | Source District Cooling [kWh] | Source District Heating [kWh] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4921.65 | 0.00 | 0.00 |
| Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 4381.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 4381.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 143.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3095.41 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 8905.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4921.65 | 0.00 | 3095.41 |
| Source Electricity [kWh/m2] | Source Natural Gas [kWh/m2] | Source Gasoline [kWh/m2] | Source Diesel [kWh/m2] | Source Coal [kWh/m2] | Source Fuel Oil No 1 [kWh/m2] | Source Fuel Oil No 2 [kWh/m2] | Source Propane [kWh/m2] | Source Other Fuel 1 [kWh/m2] | Source Other Fuel 2 [kWh/m2] | Source District Cooling [kWh/m2] | Source District Heating [kWh/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.45 | 0.00 | 0.00 |
| Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 34.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 34.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 1.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.18 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 69.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.45 | 0.00 | 24.18 |
| Source Electricity [kWh/m2] | Source Natural Gas [kWh/m2] | Source Gasoline [kWh/m2] | Source Diesel [kWh/m2] | Source Coal [kWh/m2] | Source Fuel Oil No 1 [kWh/m2] | Source Fuel Oil No 2 [kWh/m2] | Source Propane [kWh/m2] | Source Other Fuel 1 [kWh/m2] | Source Other Fuel 2 [kWh/m2] | Source District Cooling [kWh/m2] | Source District Heating [kWh/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.63 | 0.00 | 0.00 |
| Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 22.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 22.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 0.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.12 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 46.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.63 | 0.00 | 16.12 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
ZoneHVAC:Baseboard:Convective:Water| Design Size Maximum Water Flow Rate [m3/s] | Design Size U-Factor Times Area Value [W/K] | User-Specified U-Factor Times Area Value [W/K] | |
| UT1_ZONE1_SUELO_RADIANTE | 0.000482 | 603.39 | 578.19 |
| Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
| LOOP_HW1_SYSTEM1_SISTEMA_MIXTO_CALEFACCION | 0.000482 | 0.057861 |
| Design Flow Rate [m3/s] | Design Power Consumption [W] | |
| LOOP_HW1_SYSTEM1_SISTEMA_MIXTO_CALEFACCION SUPPLY PUMP | 0.000482 | 0.000000 |
| Design Size Nominal Capacity [W] | User-Specified Nominal Capacity [W] | Design Size Design Water Flow Rate [m3/s] | |
| EQ1_SYSTEM1_CALDERA_DE_BIOMASA | 9920.00 | 25000.00 | 0.000482 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| Possible Shadow Receivers | |
| Z01_S02_E04_G1 OH | Z01_S02_E04 | |
| Mir-Z01_S02_E04_G1 OH | Z01_S01_E07 | Z01_S02_E04 | |
| Z01_S02_E04_G1 OL Left | Z01_S01_E07 | Z01_S02_E04 | |
| Mir-Z01_S02_E04_G1 OL Left | Z01_S02_E04_G1 OH | Z01_S02_E04_G1 OL Right | Z01_S01_E07 | Z01_S02_E04 | |
| Z01_S02_E04_G1 OL Right | Z01_S02_E04_G1 OH | Mir-Z01_S02_E04_G1 OL Left | Z01_S01_E07 | Z01_S02_E04 | |
| Mir-Z01_S02_E04_G1 OL Right | Z01_S01_E07 | Z01_S02_E04 | |
| Z01_S02_E04 | Z01_S02_E04_G1 OH | Z01_S02_E04_G1 OL Left | Mir-Z01_S02_E04_G1 OL Left | Z01_S02_E04_G1 OL Right | Mir-Z01_S02_E04_G1 OL Right | |
| Possible Shadow Receivers | |
| Z01_S01_E07 | Z01_S01_E07_G1 | |
| Z01_S01_E08 | Z01_S01_E08_G1 | |
| Z01_S01_E09 | Z01_S01_E09_G1 | Z01_S01_E09_G2 | |
| Z01_S02_E03 | Z01_S02_E03_G1 | Z01_S02_E03_G2 | |
| Z01_S02_E04 | Z01_S02_E04_G1 | |
| Z01_S02_E05 | Z01_S02_E05_G1 | |
| Z01_S02_E06 | Z01_S02_E06_G1 | |
| Z01_S01_E02 | Z01_S01_E02_G1 | |
| Z01_S01_E03 | Z01_S01_E03_G1 | Z01_S01_E03_G2 | |
| Z01_S01_E04 | Z01_S01_E04_G1 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Version| Version ID | |
| 1 | 23.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 4 | 15 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | No | No | No | Yes | No |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 4 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 1.000 | 1.000 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 | 10.50 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | E1_peninsula - ESP CTE_DB_HE WMO#= | 40.68 | -4.13 | 1.00 | 667.00 | 93565 | 1.1121 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Schedule | SCHED9_WATER_MAINS_TEMP | 0.00 | 0.00 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | Vivienda aislada - Guía de aplicación DB HE 2019. EJEMPLOS (I) | 0.000 | Country | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | DOE-2 |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Algorithm {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
Space Heat Balance Sizing |
Space Heat Balance Simulation |
|
| 1 | ThirdOrderBackwardDifference | No | No |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.140 | 270.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | LowerLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 6 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 2 | 39 | 13 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | Z01_VIVIENDA | 0.0 | 0.00 | 0.00 | 0.00 | 3.40 | 2.09E-006 | 1.23 | 1 | 1 | 1 | -4.50 | 73.60 | -4.50 | 4.50 | -13.86 | 8.86 | 2.67 | 341.52 | TARP | DOE-2 | 128.00 | 182.57 | 147.97 | 27.80 | 19 | 13 | 6 | Yes |
| 2 | Z02_CAMARA_SANITARIA | 0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.53 | 1 | 1 | 1 | -4.00 | 4.00 | -4.00 | 4.00 | -1.00 | 0.00 | 0.50 | 32.00 | TARP | DOE-2 | 64.00 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | Z01_VIVIENDA | 128.00 | 4.5 | 28.490 | 3.510E-002 | 4.400 | 0.000 | 0.000 | 4.400 | 0.000 | 0.000 | 8.800 | No |
| 2 | Z02_CAMARA_SANITARIA | 64.00 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | Z01_VIVIENDA_IG1 PEOPLE | SCHED5 | Z01_VIVIENDA | 128.00 | 4.5 | 4.5 | 3.510E-002 | 28.490 | 0.600 | 0.400 | 0.613 | Z01_VIVIENDA_IG1 ACTIVITYLEVEL | No | 0.0000 | 1 | 4 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | Z01_VIVIENDA_IG2 LIGHTS | SCHED6 | Z01_VIVIENDA | 128.00 | 4.5 | 563.200 | 4.400 | 125.356 | 0.000 | 0.656 | 0.180 | 0.164 | 0.000 | 1 | 56.320 | 563.200 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | Z01_VIVIENDA_IG3 ELECEQ | SCHED6 | Z01_VIVIENDA | 128.00 | 4.5 | 563.200 | 4.400 | 125.356 | 0.000 | 0.700 | 0.000 | 0.300 | 56.320 | 563.200 |
| Zone/Enclosure Name | Original Check Value | Calculated Fixed Check Value | Final Check Value | Number of Iterations | Fixed RowSum Convergence | Used RowSum Convergence | |
| 1 | Z01_VIVIENDA | 7.105427E-015 | 7.590063E-004 | 7.590063E-004 | 16 | 7.590063E-004 | 7.590063E-004 |
| 2 | Z02_CAMARA_SANITARIA | 8.881784E-016 | 7.986024E-004 | 7.986024E-004 | 12 | 7.986024E-004 | 7.986024E-004 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Zone/Enclosure Name | Original Check Value | Calculated Fixed Check Value | Final Check Value | Number of Iterations | Fixed RowSum Convergence | Used RowSum Convergence | |
| 1 | Z01_VIVIENDA | 7.105427E-015 | 7.590063E-004 | 7.590063E-004 | 16 | 7.590063E-004 | 7.590063E-004 |
| 2 | Z02_CAMARA_SANITARIA | 8.881784E-016 | 7.986024E-004 | 7.986024E-004 | 12 | 7.986024E-004 | 7.986024E-004 |
| Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
| 1 | Z01_S01_E06 | 2 | 54.10 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 4 | No | No |
| 2 | Z01_S01_E07 | 2 | 105.09 | 200.88 | 22.71 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 4 | No | No |
| 3 | Z01_S01_E07_G1 | 2 | 105.09 | 200.88 | 22.71 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 2 | No | No |
| 4 | Z01_S01_E08 | 2 | 30.07 | 27.36 | 4.50 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 4 | No | No |
| 5 | Z01_S01_E08_G1 | 2 | 30.07 | 27.36 | 4.50 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 2 | No | No |
| 6 | Z01_S01_E09 | 2 | 52.00 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 4 | No | No |
| 7 | Z01_S01_E09_G1 | 2 | 52.00 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 2 | No | No |
| 8 | Z01_S01_E09_G2 | 2 | 52.00 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 2 | No | No |
| 9 | Z01_S02_E03 | 2 | 54.10 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 4 | No | No |
| 10 | Z01_S02_E03_G1 | 2 | 54.10 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 0 | No | No |
| 11 | Z01_S02_E03_G2 | 2 | 54.10 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 1 | No | No |
| 12 | Z01_S02_E04 | 2 | 105.09 | 200.88 | 22.71 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 4 | No | No |
| 13 | Z01_S02_E04_G1 | 2 | 105.09 | 200.88 | 22.71 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 1 | No | No |
| 14 | Z01_S02_E05 | 2 | 30.07 | 27.36 | 4.50 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 4 | No | No |
| 15 | Z01_S02_E05_G1 | 2 | 30.07 | 27.36 | 4.50 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 1 | No | No |
| 16 | Z01_S02_E06 | 2 | 52.00 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 4 | No | No |
| 17 | Z01_S02_E06_G1 | 2 | 52.00 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 1 | No | No |
| 18 | Z01_S01_E02_G1_TB1_LATERALES V | 2 | 105.09 | 200.88 | 22.71 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 3 | No | No |
| 19 | Z01_S01_TB01 EF | 2 | 105.09 | 200.88 | 22.71 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 3 | No | No |
| 20 | Z01_S01_TB03 FF | 2 | 105.09 | 200.88 | 22.71 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 3 | No | No |
| 21 | Z01_S01_TB04 FC | 2 | 105.09 | 200.88 | 22.71 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 3 | No | No |
| 22 | Z01_S01_E01 | 1 | 0.00 | 0.00 | 0.00 | 1 | 2.67 | 65.20 | 2.94 | 0.15 | 0 | No | No |
| 23 | Z01_S02_E01 | 1 | 0.00 | 0.00 | 0.00 | 1 | 2.67 | 65.20 | 2.94 | 0.15 | 0 | No | No |
| 24 | Z01_S01_E02 | 2 | 24.82 | 36.16 | 4.00 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 0 | No | No |
| 25 | Z01_S01_E02_G1 | 2 | 24.82 | 36.16 | 3.57 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 2 | No | No |
| 26 | Z01_S01_E03 | 2 | 52.00 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 0 | No | No |
| 27 | Z01_S01_E03_G1 | 2 | 52.00 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 2 | No | No |
| 28 | Z01_S01_E03_G2 | 2 | 52.00 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 2 | No | No |
| 29 | Z01_S01_E04 | 2 | 105.09 | 200.88 | 22.71 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 0 | No | No |
| 30 | Z01_S01_E04_G1 | 2 | 24.82 | 36.16 | 3.57 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 2 | No | No |
| 31 | Z01_S01_E05 | 2 | 54.10 | 36.07 | 8.86 | 2 | 2.67 | 65.20 | 2.94 | 0.15 | 0 | No | No |
| 32 | iz-Z01_S01_E01 | 1 | 0.00 | 0.00 | 0.00 | 1 | 2.67 | 65.20 | 2.94 | 0.15 | 0 | No | No |
| 33 | Z01_VIVIENDA FURNITURE | 1 | 0.00 | 0.00 | 0.00 | 1 | 2.67 | 65.20 | 2.94 | 0.15 | 0 | No | No |
| 34 | Z02_S01_E03 | 2 | 0.00 | 0.00 | 0.00 | 2 | 0.50 | 0.00 | 8.00 | -999.00 | 0 | No | No |
| 35 | Z02_S01_E04 | 2 | 0.00 | 0.00 | 0.00 | 2 | 0.50 | 0.00 | 8.00 | -999.00 | 0 | No | No |
| 36 | Z02_S01_E05 | 2 | 0.00 | 0.00 | 0.00 | 2 | 0.50 | 0.00 | 8.00 | -999.00 | 0 | No | No |
| 37 | Z02_S01_E06 | 2 | 0.00 | 0.00 | 0.00 | 2 | 0.50 | 0.00 | 8.00 | -999.00 | 0 | No | No |
| 38 | Z02_S01_E01 | 2 | 0.00 | 0.00 | 0.00 | 2 | 0.50 | 0.00 | 8.00 | -999.00 | 0 | No | No |
| 39 | iz-Z01_S02_E01 | 1 | 0.00 | 0.00 | 0.00 | 1 | 0.50 | 0.00 | 8.00 | -999.00 | 0 | No | No |
| Perimeter | Height | Xmin | Xmax | Ymin | Ymax | Zmin | Zmax | |
| 1 | 27.36 | 4.50 | -4.00 | 4.00 | 0.00 | 4.50 | 0.00 | 4.50 |
| Perimeter | Height | Xmin | Xmax | Ymin | Ymax | Zmin | Zmax | |
| 1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Perimeter | Height | Xmin | Xmax | Ymin | Ymax | Zmin | Zmax | |
| 1 | 36.07 | 8.86 | 0.00 | 4.50 | -4.00 | 4.00 | 0.00 | 8.86 |
| Perimeter | Height | Xmin | Xmax | Ymin | Ymax | Zmin | Zmax | |
| 1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Perimeter | Height | Xmin | Xmax | Ymin | Ymax | Zmin | Zmax | |
| 1 | 200.88 | 22.71 | -4.00 | 73.60 | -4.50 | 0.00 | -13.86 | 8.86 |
| Perimeter | Height | Xmin | Xmax | Ymin | Ymax | Zmin | Zmax | |
| 1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Perimeter | Height | Xmin | Xmax | Ymin | Ymax | Zmin | Zmax | |
| 1 | 36.07 | 8.86 | -4.50 | 0.00 | -4.00 | 4.00 | 0.00 | 8.86 |
| Area [m2] | Perimeter [m] | Height [m] | Tilt [deg] | Azimuth [deg] | |
| 1 | 24.82 | 36.16 | 3.57 | 45.00 | 11.58! <ZoneInfiltration Airflow Stats Nominal> |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
| 1 | Z01_VIVIENDA_IG5 VENTIL | SCHED7 | Z01_VIVIENDA | 128.00 | 4.5 | 3.600E-002 | 2.813E-004 | 8.013E-003 | 0.379 | Exhaust | 151.278 | 0.7 | 1.000 | 0.000 | 0.000 | 0.000 | -50.00 | 100.00 | -50.00 | -50.00 | 100.00 | 40.00 |
| 2 | Z01_VIVIENDA_IG6 VENTIL | SCHED8 | Z01_VIVIENDA | 128.00 | 4.5 | 0.379 | 2.965E-003 | 8.446E-002 | 4.000 | Natural | 0.000 | 1.0 | 1.000 | 0.000 | 0.000 | 0.000 | -50.00 | 100.00 | -50.00 | -50.00 | 100.00 | 40.00 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | Z01_VIVIENDA | Mixing/Well-Stirred |
| 2 | Z02_CAMARA_SANITARIA | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 4 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.0000 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.0000 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | Z01_VIVIENDA | Cooling | 1739.42497 | 1739.42497 | 0.12235 | 0.12235 | SUMMER | 9/4 16:00:00 | 31.30000 | 7.67334E-003 | 128.00000 | 4.49280 | 0.00000 | 0.00000 |
| 2 | Z01_VIVIENDA | Heating | 4509.96632 | 4509.96632 | 0.13060 | 0.13060 | WINTER | 1/12 08:00:00 | -4.40000 | 2.39724E-003 | 128.00000 | 4.49280 | 0.00000 | 0.00000 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | ZoneHVAC:Baseboard:Convective:Water | UT1_ZONE1_SUELO_RADIANTE | Design Size Maximum Water Flow Rate [m3/s] | 0.00048 |
| 2 | ZoneHVAC:Baseboard:Convective:Water | UT1_ZONE1_SUELO_RADIANTE | Design Size U-Factor Times Area Value [W/K] | 603.39059 |
| 3 | ZoneHVAC:Baseboard:Convective:Water | UT1_ZONE1_SUELO_RADIANTE | User-Specified U-Factor Times Area Value [W/K] | 578.19100 |
| 4 | PlantLoop | LOOP_HW1_SYSTEM1_SISTEMA_MIXTO_CALEFACCION | Maximum Loop Flow Rate [m3/s] | 0.00048 |
| 5 | PlantLoop | LOOP_HW1_SYSTEM1_SISTEMA_MIXTO_CALEFACCION | Plant Loop Volume [m3] | 0.05786 |
| 6 | Pump:ConstantSpeed | LOOP_HW1_SYSTEM1_SISTEMA_MIXTO_CALEFACCION SUPPLY PUMP | Design Flow Rate [m3/s] | 0.00048 |
| 7 | Pump:ConstantSpeed | LOOP_HW1_SYSTEM1_SISTEMA_MIXTO_CALEFACCION SUPPLY PUMP | Design Power Consumption [W] | 0.00000 |
| 8 | Boiler:HotWater | EQ1_SYSTEM1_CALDERA_DE_BIOMASA | Design Size Nominal Capacity [W] | 9920.00000 |
| 9 | Boiler:HotWater | EQ1_SYSTEM1_CALDERA_DE_BIOMASA | User-Specified Nominal Capacity [W] | 25000.00000 |
| 10 | Boiler:HotWater | EQ1_SYSTEM1_CALDERA_DE_BIOMASA | Design Size Design Water Flow Rate [m3/s] | 0.00048 |
| Zone Name | # Surfaces | |
| 1 | Z01_VIVIENDA | 33 |
| 2 | Z02_CAMARA_SANITARIA | 6 |
| Number of Shading Surfaces | # Surfaces | |
| 1 | Number of Shading Surfaces | 6 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | Z01_S01_E06 | Wall | CTF - ConductionTransferFunction | C05_MURO_EXTERIOR | 0.226 | 0.219 | 12.02 | 12.02 | 12.02 | 270.00 | 90.00 | 8.00 | 1.50 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 2 | Z01_S01_E07 | Wall | CTF - ConductionTransferFunction | C05_MURO_EXTERIOR | 0.226 | 0.219 | 10.52 | 12.02 | 10.82 | 180.00 | 90.00 | 8.00 | 1.50 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 3 | Z01_S01_E07_G1 | Window | Z01_S01_E07 | Window5 Detailed Fenestration | H04_WINDOW | N/A | 0.999 | No | 1.20 | 1.20 | 1.20 | 180.00 | 90.00 | 0.87 | 1.37 | 2.50E-002 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.52 | 0.48 | 4 |
| 4 | Z01_S01_E08 | Wall | CTF - ConductionTransferFunction | C05_MURO_EXTERIOR | 0.226 | 0.219 | 10.52 | 12.02 | 10.82 | 0.00 | 90.00 | 8.00 | 1.50 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 5 | Z01_S01_E08_G1 | Window | Z01_S01_E08 | Window5 Detailed Fenestration | H05_WINDOW | N/A | 0.999 | No | 1.20 | 1.20 | 1.20 | 0.00 | 90.00 | 0.87 | 1.37 | 2.50E-002 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.52 | 0.48 | 4 |
| 6 | Z01_S01_E09 | Wall | CTF - ConductionTransferFunction | C05_MURO_EXTERIOR | 0.226 | 0.219 | 9.02 | 12.02 | 9.62 | 90.00 | 90.00 | 8.00 | 1.50 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 7 | Z01_S01_E09_G1 | Window | Z01_S01_E09 | Window5 Detailed Fenestration | H04_WINDOW | N/A | 0.999 | No | 1.20 | 1.20 | 1.20 | 90.00 | 90.00 | 0.87 | 1.37 | 2.50E-002 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.52 | 0.48 | 4 |
| 8 | Z01_S01_E09_G2 | Window | Z01_S01_E09 | Window5 Detailed Fenestration | H04_WINDOW | N/A | 0.999 | No | 1.20 | 1.20 | 1.20 | 90.00 | 90.00 | 0.87 | 1.37 | 2.50E-002 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.52 | 0.48 | 4 |
| 9 | Z01_S02_E03 | Wall | CTF - ConductionTransferFunction | C05_MURO_EXTERIOR | 0.226 | 0.219 | 15.60 | 20.00 | 16.15 | 270.00 | 90.00 | 8.00 | 2.50 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 10 | Z01_S02_E03_G1 | Door | Z01_S02_E03 | CTF - ConductionTransferFunction | H01_DOOR | 3.514 | 3.514 | 2.20 | 2.20 | 2.20 | 270.00 | 90.00 | 1.00 | 2.20 | 0.47 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.73 | 0.27 | 4 | |
| 11 | Z01_S02_E03_G2 | Window | Z01_S02_E03 | Window5 Detailed Fenestration | H06_WINDOW | N/A | 0.999 | No | 1.65 | 1.65 | 1.65 | 270.00 | 90.00 | 0.82 | 2.02 | 0.47 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.76 | 0.24 | 4 |
| 12 | Z01_S02_E04 | Wall | CTF - ConductionTransferFunction | C05_MURO_EXTERIOR | 0.226 | 0.219 | 9.00 | 20.00 | 11.75 | 180.00 | 90.00 | 8.00 | 2.50 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.54 | 0.46 | 4 | ||
| 13 | Z01_S02_E04_G1 | Window | Z01_S02_E04 | Window5 Detailed Fenestration | H07_WINDOW | N/A | 0.999 | No | 8.25 | 8.25 | 8.25 | 180.00 | 90.00 | 4.60 | 1.80 | 0.47 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.81 | 0.19 | 4 |
| 14 | Z01_S02_E05 | Wall | CTF - ConductionTransferFunction | C05_MURO_EXTERIOR | 0.226 | 0.219 | 13.40 | 20.00 | 15.05 | 0.00 | 90.00 | 8.00 | 2.50 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 15 | Z01_S02_E05_G1 | Window | Z01_S02_E05 | Window5 Detailed Fenestration | H08_WINDOW | N/A | 0.999 | No | 4.95 | 4.95 | 4.95 | 0.00 | 90.00 | 2.66 | 1.86 | 0.47 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.66 | 0.34 | 4 |
| 16 | Z01_S02_E06 | Wall | CTF - ConductionTransferFunction | C05_MURO_EXTERIOR | 0.226 | 0.219 | 13.40 | 20.00 | 15.05 | 90.00 | 90.00 | 8.00 | 2.50 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 17 | Z01_S02_E06_G1 | Window | Z01_S02_E06 | Window5 Detailed Fenestration | H08_WINDOW | N/A | 0.999 | No | 4.95 | 4.95 | 4.95 | 90.00 | 90.00 | 2.66 | 1.86 | 0.47 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.50 | 0.50 | 0.66 | 0.34 | 4 |
| 18 | Z01_S01_E02_G1_TB1_LATERALES V | Wall | CTF - ConductionTransferFunction | C08_TBW_1_96323U_ | 0.509 | 0.473 | 22.08 | 22.08 | 22.08 | 180.00 | 90.00 | 0.30 | 73.60 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 19 | Z01_S01_TB01 EF | Wall | CTF - ConductionTransferFunction | C09_TBW_5_85U_ | 0.171 | 0.167 | 4.80 | 4.80 | 4.80 | 180.00 | 90.00 | 0.30 | 16.01 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 20 | Z01_S01_TB03 FF | Wall | CTF - ConductionTransferFunction | C09_TBW_5_85U_ | 0.171 | 0.167 | 19.20 | 19.20 | 19.20 | 180.00 | 90.00 | 0.30 | 64.00 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 21 | Z01_S01_TB04 FC | Wall | CTF - ConductionTransferFunction | C07_TBW_1_17882U_ | 0.848 | 0.753 | 8.40 | 8.40 | 8.40 | 180.00 | 90.00 | 0.30 | 28.00 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
| 22 | Z01_S01_E01 | Floor | CTF - ConductionTransferFunction | C03_FORJADO_INTERIOR (INV) | 0.404 | 0.367 | 64.00 | 64.00 | 64.00 | 90.00 | 180.00 | 8.00 | 8.00 | 0.00 | iz-Z01_S01_E01 | Other/Same Surface Int Conv | User Supplied Value | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 23 | Z01_S02_E01 | Floor | CTF - ConductionTransferFunction | C02_FORJADO_CON_CAMARA_SANIT (INV) | 0.233 | 0.220 | 64.00 | 64.00 | 64.00 | 90.00 | 180.00 | 8.00 | 8.00 | 0.00 | iz-Z01_S02_E01 | Other/Same Surface Int Conv | User Supplied Value | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 24 | Z01_S01_E02 | Roof | CTF - ConductionTransferFunction | C01_CUBIERTA_INCLINADA_DE_TE | 0.172 | 0.166 | 21.63 | 22.63 | 21.83 | 3.58E-010 | 45.00 | 8.00 | 6.93 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.00 | 0.85 | 0.15 | 0.85 | 3 | ||
| 25 | Z01_S01_E02_G1 | Window | Z01_S01_E02 | Window5 Detailed Fenestration | H02_SKYLIGHT | N/A | 0.999 | No | 0.80 | 0.80 | 0.80 | 0.00 | 45.00 | 0.89 | 0.89 | 2.50E-002 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.00 | 0.85 | 0.18 | 0.82 | 4 |
| 26 | Z01_S01_E03 | Roof | CTF - ConductionTransferFunction | C01_CUBIERTA_INCLINADA_DE_TE | 0.172 | 0.166 | 20.62 | 22.63 | 21.03 | 90.00 | 45.00 | 8.00 | 6.93 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.00 | 0.85 | 0.15 | 0.85 | 3 | ||
| 27 | Z01_S01_E03_G1 | Window | Z01_S01_E03 | Window5 Detailed Fenestration | H03_SKYLIGHT | N/A | 0.999 | No | 0.80 | 0.80 | 0.80 | 90.00 | 45.00 | 0.89 | 0.89 | 2.50E-002 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.00 | 0.85 | 0.18 | 0.82 | 4 |
| 28 | Z01_S01_E03_G2 | Window | Z01_S01_E03 | Window5 Detailed Fenestration | H03_SKYLIGHT | N/A | 0.999 | No | 0.80 | 0.80 | 0.80 | 90.00 | 45.00 | 0.89 | 0.89 | 2.50E-002 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.00 | 0.85 | 0.18 | 0.82 | 4 |
| 29 | Z01_S01_E04 | Roof | CTF - ConductionTransferFunction | C01_CUBIERTA_INCLINADA_DE_TE | 0.172 | 0.166 | 21.63 | 22.63 | 21.83 | 180.00 | 45.00 | 8.00 | 6.93 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.00 | 0.85 | 0.15 | 0.85 | 3 | ||
| 30 | Z01_S01_E04_G1 | Window | Z01_S01_E04 | Window5 Detailed Fenestration | H03_SKYLIGHT | N/A | 0.999 | No | 0.80 | 0.80 | 0.80 | 180.00 | 45.00 | 0.89 | 0.89 | 2.50E-002 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.00 | 0.85 | 0.18 | 0.82 | 4 |
| 31 | Z01_S01_E05 | Roof | CTF - ConductionTransferFunction | C01_CUBIERTA_INCLINADA_DE_TE | 0.172 | 0.166 | 22.63 | 22.63 | 22.63 | 270.00 | 45.00 | 8.00 | 6.93 | 0.00 | ExternalEnvironment | User Supplied Value | User Supplied Value | SunExposed | WindExposed | 0.00 | 0.85 | 0.15 | 0.85 | 3 | ||
| 32 | iz-Z01_S01_E01 | Roof | CTF - ConductionTransferFunction | iz-C03_FORJADO_INTERIOR (INV) | 0.404 | 0.375 | 64.00 | 64.00 | 64.00 | 270.00 | 0.00 | 8.00 | 8.00 | 0.00 | Z01_S01_E01 | Other/Same Surface Int Conv | User Supplied Value | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
| 33 | Z01_VIVIENDA FURNITURE | Internal Mass | CTF - ConductionTransferFunction | FURNIT_INTERNALMASS | 3.600 | 3.600 | 64.00 | 64.00 | 64.00 | 0.00 | 90.00 | 64.00 | 1.00 | 0.00 | Z01_VIVIENDA FURNITURE | Other/Same Surface Int Conv | User Supplied Value | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
| 34 | Z02_S01_E03 | Wall | CTF - ConductionTransferFunction | C04_MURO_DE_CAMARA_SANITARIA | 1.049 | 0.907 | 4.00 | 4.00 | 4.00 | 270.00 | 90.00 | 8.00 | 0.50 | 0.00 | Ground | N/A-Ground | User Supplied Value | NoSun | NoWind | 1.00 | 0.50 | 0.50 | 0.50 | 4 | ||
| 35 | Z02_S01_E04 | Wall | CTF - ConductionTransferFunction | C04_MURO_DE_CAMARA_SANITARIA | 1.049 | 0.907 | 4.00 | 4.00 | 4.00 | 180.00 | 90.00 | 8.00 | 0.50 | 0.00 | Ground | N/A-Ground | User Supplied Value | NoSun | NoWind | 1.00 | 0.50 | 0.50 | 0.50 | 4 | ||
| 36 | Z02_S01_E05 | Wall | CTF - ConductionTransferFunction | C04_MURO_DE_CAMARA_SANITARIA | 1.049 | 0.907 | 4.00 | 4.00 | 4.00 | 0.00 | 90.00 | 8.00 | 0.50 | 0.00 | Ground | N/A-Ground | User Supplied Value | NoSun | NoWind | 1.00 | 0.50 | 0.50 | 0.50 | 4 | ||
| 37 | Z02_S01_E06 | Wall | CTF - ConductionTransferFunction | C04_MURO_DE_CAMARA_SANITARIA | 1.049 | 0.907 | 4.00 | 4.00 | 4.00 | 90.00 | 90.00 | 8.00 | 0.50 | 0.00 | Ground | N/A-Ground | User Supplied Value | NoSun | NoWind | 1.00 | 0.50 | 0.50 | 0.50 | 4 | ||
| 38 | Z02_S01_E01 | Floor | CTF - ConductionTransferFunction | C06_SOLERA_DE_CAMARA_SANITAR (INV) | 0.663 | 0.571 | 64.00 | 64.00 | 64.00 | 90.00 | 180.00 | 8.00 | 8.00 | 0.00 | Ground | N/A-Ground | User Supplied Value | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
| 39 | iz-Z01_S02_E01 | Roof | CTF - ConductionTransferFunction | iz-C02_FORJADO_CON_CAMARA_SANIT (INV) | 0.233 | 0.223 | 64.00 | 64.00 | 64.00 | 270.00 | 0.00 | 8.00 | 8.00 | 0.00 | Z01_S02_E01 | Other/Same Surface Int Conv | User Supplied Value | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Transmittance Schedule | Min Schedule Value | Max Schedule Value | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
| 1 | Z01_S02_E04_G1 OH | Shading | Z01_S02_E04 | None | 0.0 | 0.0 | 4.60 | 4.60 | 4.60 | 180.00 | 180.00 | 4.60 | 1.00 | 4 | ||||||||||||
| 2 | Mir-Z01_S02_E04_G1 OH | Shading | Z01_S02_E04 | None | 0.0 | 0.0 | 4.60 | 4.60 | 4.60 | 0.00 | 0.00 | 4.60 | 1.00 | 4 | ||||||||||||
| 3 | Z01_S02_E04_G1 OL Left | Shading | Z01_S02_E04 | None | 0.0 | 0.0 | 1.80 | 1.80 | 1.80 | 270.00 | 90.00 | 1.00 | 1.80 | 4 | ||||||||||||
| 4 | Mir-Z01_S02_E04_G1 OL Left | Shading | Z01_S02_E04 | None | 0.0 | 0.0 | 1.80 | 1.80 | 1.80 | 90.00 | 90.00 | 1.00 | 1.80 | 4 | ||||||||||||
| 5 | Z01_S02_E04_G1 OL Right | Shading | Z01_S02_E04 | None | 0.0 | 0.0 | 1.80 | 1.80 | 1.80 | 270.00 | 90.00 | 1.00 | 1.80 | 4 | ||||||||||||
| 6 | Mir-Z01_S02_E04_G1 OL Right | Shading | Z01_S02_E04 | None | 0.0 | 0.0 | 1.80 | 1.80 | 1.80 | 90.00 | 90.00 | 1.00 | 1.80 | 4 |
| Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | |
| 1 | R08_VENTANA_P03_SUR_Y_ESTE (63MM) | Frame | Z01_S01_E07_G1 | Window5 Detailed Fenestration | N/A | N/A | 0.30 | 0.30 | * | N/A | N/A | 6.30E-002 | N/A | |||
| 2 | R07_VENTANA_P03_NORTE (63MM) | Frame | Z01_S01_E08_G1 | Window5 Detailed Fenestration | N/A | N/A | 0.30 | 0.30 | * | N/A | N/A | 6.30E-002 | N/A | |||
| 3 | R08_VENTANA_P03_SUR_Y_ESTE (63MM) | Frame | Z01_S01_E09_G1 | Window5 Detailed Fenestration | N/A | N/A | 0.30 | 0.30 | * | N/A | N/A | 6.30E-002 | N/A | |||
| 4 | R08_VENTANA_P03_SUR_Y_ESTE (63MM) | Frame | Z01_S01_E09_G2 | Window5 Detailed Fenestration | N/A | N/A | 0.30 | 0.30 | * | N/A | N/A | 6.30E-002 | N/A | |||
| 5 | R05_VENTANA_P02_OESTE (91MM) | Frame | Z01_S02_E03_G2 | Window5 Detailed Fenestration | N/A | N/A | 0.55 | 0.55 | * | N/A | N/A | 9.10E-002 | N/A | |||
| 6 | R06_VENTANA_P02_SUR (202MM) | Frame | Z01_S02_E04_G1 | Window5 Detailed Fenestration | N/A | N/A | 2.75 | 2.75 | * | N/A | N/A | 0.20 | N/A | |||
| 7 | R04_VENTANA_P02_NORTE_Y_ESTE (170MM) | Frame | Z01_S02_E05_G1 | Window5 Detailed Fenestration | N/A | N/A | 1.65 | 1.65 | * | N/A | N/A | 0.17 | N/A | |||
| 8 | R04_VENTANA_P02_NORTE_Y_ESTE (170MM) | Frame | Z01_S02_E06_G1 | Window5 Detailed Fenestration | N/A | N/A | 1.65 | 1.65 | * | N/A | N/A | 0.17 | N/A | |||
| 9 | R01_LUCERNARIO_NORTE (53MM) | Frame | Z01_S01_E02_G1 | Window5 Detailed Fenestration | N/A | N/A | 0.20 | 0.20 | * | N/A | N/A | 5.30E-002 | N/A | |||
| 10 | R02_LUCERNARIO_SUR_Y_ESTE (53MM) | Frame | Z01_S01_E03_G1 | Window5 Detailed Fenestration | N/A | N/A | 0.20 | 0.20 | * | N/A | N/A | 5.30E-002 | N/A | |||
| 11 | R02_LUCERNARIO_SUR_Y_ESTE (53MM) | Frame | Z01_S01_E03_G2 | Window5 Detailed Fenestration | N/A | N/A | 0.20 | 0.20 | * | N/A | N/A | 5.30E-002 | N/A | |||
| 12 | R02_LUCERNARIO_SUR_Y_ESTE (53MM) | Frame | Z01_S01_E04_G1 | Window5 Detailed Fenestration | N/A | N/A | 0.20 | 0.20 | * | N/A | N/A | 5.30E-002 | N/A |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2007 | 12/31/2007 | Monday | 365 | Use RunPeriod Specified Day | Yes | Yes | No | Yes | Yes | Clark and Allen |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | WeatherFile | 03/25 | 10/28 |
| NumberofWarmupDays | |
| 1 | 11 |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | Z01_VIVIENDA | RunPeriod: RUNPERIOD 1 | 5.3506327369E-002 | 0.2560113116 | Pass | Pass | 4.8475809247E-002 | 0.2166953554 | Pass | Pass |
| 2 | Z02_CAMARA_SANITARIA | RunPeriod: RUNPERIOD 1 | 2.9151464038E-003 | 1.0954041877E-004 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Report
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Annual Heat Emissions Summary| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [kWh] | 51443.95 | 8131.22 | 0.00 | 0.00 | 309.54 | 59885.59 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7°C, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] | Danger (> 39.4°C, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| Z01_VIVIENDA | 8692.50 | 67.50 | 0.00 | 0.00 | 0.00 |
| Z02_CAMARA_SANITARIA | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 8692.50 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 67.50 | 0.00 | 0.00 | 0.00 |
| Average | 8726.25 | 33.75 | 0.00 | 0.00 | 0.00 |
| Sum | 17452.50 | 67.50 | 0.00 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7°C, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] | Danger (> 39.4°C, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| Z01_VIVIENDA | 27410.29 | 220.43 | 0.00 | 0.00 | 0.00 |
| Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 27410.29 | 220.43 | 0.00 | 0.00 | 0.00 |
| Average | 13705.15 | 110.21 | 0.00 | 0.00 | 0.00 |
| Sum | 27410.29 | 220.43 | 0.00 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7°C, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] | Danger (> 39.4°C, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| Z01_VIVIENDA | 8692.50 | 67.50 | 0.00 | 0.00 | 0.00 |
| Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8692.50 | 67.50 | 0.00 | 0.00 | 0.00 |
| Average | 4346.25 | 33.75 | 0.00 | 0.00 | 0.00 |
| Sum | 8692.50 | 67.50 | 0.00 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| Z01_VIVIENDA | 8686.75 | 73.25 | 0.00 | 0.00 | 0.00 |
| Z02_CAMARA_SANITARIA | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 8686.75 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 73.25 | 0.00 | 0.00 | 0.00 |
| Average | 8723.38 | 36.62 | 0.00 | 0.00 | 0.00 |
| Sum | 17446.75 | 73.25 | 0.00 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| Z01_VIVIENDA | 27329.42 | 301.30 | 0.00 | 0.00 | 0.00 |
| Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 27329.42 | 301.30 | 0.00 | 0.00 | 0.00 |
| Average | 13664.71 | 150.65 | 0.00 | 0.00 | 0.00 |
| Sum | 27329.42 | 301.30 | 0.00 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| Z01_VIVIENDA | 8686.75 | 73.25 | 0.00 | 0.00 | 0.00 |
| Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8686.75 | 73.25 | 0.00 | 0.00 | 0.00 |
| Average | 4343.38 | 36.62 | 0.00 | 0.00 | 0.00 |
| Sum | 8686.75 | 73.25 | 0.00 | 0.00 | 0.00 |
| Hours of Safety [hr] | End Time of the Safety Duration | Safe Temperature Exceedance Hours [hr] | Safe Temperature Exceedance OccupantHours [hr] | Safe Temperature Exceedance OccupiedHours [hr] | |
| Z01_VIVIENDA | 3700.75 | 04-JUN-04:45 | 57.25 | 231.94 | 57.25 |
| Z02_CAMARA_SANITARIA | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Max | 3700.75 | - | 57.25 | 231.94 | 57.25 |
| Average | 1850.38 | - | 28.62 | 115.97 | 28.62 |
| Sum | 3700.75 | - | 57.25 | 231.94 | 57.25 |
| Hours of Safety [hr] | End Time of the Safety Duration | Safe Temperature Exceedance Hours [hr] | Safe Temperature Exceedance OccupantHours [hr] | Safe Temperature Exceedance OccupiedHours [hr] | |
| Z01_VIVIENDA | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| Z02_CAMARA_SANITARIA | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| Average | 4380.00 | - | 0.00 | 0.00 | 0.00 |
| Sum | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| Cooling Setpoint Unmet Degree-Hours [°C·hr] | Cooling Setpoint Unmet Occupant-Weighted Degree-Hours [°C·hr] | Cooling Setpoint Unmet Occupied Degree-Hours [°C·hr] | Heating Setpoint Unmet Degree-Hours [°C·hr] | Heating Setpoint Unmet Occupant-Weighted Degree-Hours [°C·hr] | Heating Setpoint Unmet Occupied Degree-Hours [°C·hr] | |
| Z01_VIVIENDA | 480.18 | 1457.69 | 480.18 | 9.16 | 19.14 | 9.16 |
| Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 480.18 | 1457.69 | 480.18 | 9.16 | 19.14 | 9.16 |
| Average | 240.09 | 728.84 | 240.09 | 4.58 | 9.57 | 4.58 |
| Sum | 480.18 | 1457.69 | 480.18 | 9.16 | 19.14 | 9.16 |
| Very-cold Exceedance OccupantHours [hr] | Cool Exceedance OccupantHours [hr] | Warm Exceedance OccupantHours [hr] | Very-hot Exceedance OccupantHours [hr] | |
| Z01_VIVIENDA | 0.00 | 0.00 | 0.00 | 0.00 |
| Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 0.00 | 0.00 | 0.00 | 0.00 |
| Average | 0.00 | 0.00 | 0.00 | 0.00 |
| Sum | 0.00 | 0.00 | 0.00 | 0.00 |
| Very-cold Exceedance OccupantHours [hr] | Cool Exceedance OccupantHours [hr] | Warm Exceedance OccupantHours [hr] | Very-hot Exceedance OccupantHours [hr] | |
| Z01_VIVIENDA | 0.00 | 0.00 | 0.00 | 0.00 |
| Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 0.00 | 0.00 | 0.00 | 0.00 |
| Average | 0.00 | 0.00 | 0.00 | 0.00 |
| Sum | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| None |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 0.00 | 0 | |||
| Feb | 0.00 | 0 | |||
| Mar | 0.00 | 0 | |||
| Apr | 0.00 | 0 | |||
| May | 0.00 | 0 | |||
| Jun | 0.00 | 0 | |||
| Jul | 0.00 | 0 | |||
| Aug | 0.00 | 0 | |||
| Sep | 0.00 | 0 | |||
| Oct | 0.00 | 0 | |||
| Nov | 0.00 | 0 | |||
| Dec | 0.00 | 0 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| Z01_S01_E06 | C05_MURO_EXTERIOR | 0.35 | 0.219 | 0.226 | 12.02 | 12.02 | 270.00 | 90.00 | W |
| Z01_S01_E07 | C05_MURO_EXTERIOR | 0.35 | 0.219 | 0.226 | 12.02 | 10.52 | 180.00 | 90.00 | S |
| Z01_S01_E08 | C05_MURO_EXTERIOR | 0.35 | 0.219 | 0.226 | 12.02 | 10.52 | 0.00 | 90.00 | N |
| Z01_S01_E09 | C05_MURO_EXTERIOR | 0.35 | 0.219 | 0.226 | 12.02 | 9.02 | 90.00 | 90.00 | E |
| Z01_S02_E03 | C05_MURO_EXTERIOR | 0.35 | 0.219 | 0.226 | 20.00 | 15.60 | 270.00 | 90.00 | W |
| Z01_S02_E04 | C05_MURO_EXTERIOR | 0.35 | 0.219 | 0.226 | 20.00 | 9.00 | 180.00 | 90.00 | S |
| Z01_S02_E05 | C05_MURO_EXTERIOR | 0.35 | 0.219 | 0.226 | 20.00 | 13.40 | 0.00 | 90.00 | N |
| Z01_S02_E06 | C05_MURO_EXTERIOR | 0.35 | 0.219 | 0.226 | 20.00 | 13.40 | 90.00 | 90.00 | E |
| Z01_S01_E02_G1_TB1_LATERALES V | C08_TBW_1_96323U_ | 0.40 | 0.473 | 0.509 | 22.08 | 22.08 | 180.00 | 90.00 | S |
| Z01_S01_TB01 EF | C09_TBW_5_85U_ | 0.40 | 0.167 | 0.171 | 4.80 | 4.80 | 180.00 | 90.00 | S |
| Z01_S01_TB03 FF | C09_TBW_5_85U_ | 0.40 | 0.167 | 0.171 | 19.20 | 19.20 | 180.00 | 90.00 | S |
| Z01_S01_TB04 FC | C07_TBW_1_17882U_ | 0.40 | 0.753 | 0.848 | 8.40 | 8.40 | 180.00 | 90.00 | S |
| Z01_S01_E02 | C01_CUBIERTA_INCLINADA_DE_TE | 0.35 | 0.168 | 0.172 | 22.63 | 21.63 | 0.00 | 45.00 | |
| Z01_S01_E03 | C01_CUBIERTA_INCLINADA_DE_TE | 0.35 | 0.168 | 0.172 | 22.63 | 20.62 | 90.00 | 45.00 | |
| Z01_S01_E04 | C01_CUBIERTA_INCLINADA_DE_TE | 0.35 | 0.168 | 0.172 | 22.63 | 21.63 | 180.00 | 45.00 | |
| Z01_S01_E05 | C01_CUBIERTA_INCLINADA_DE_TE | 0.35 | 0.168 | 0.172 | 22.63 | 22.63 | 270.00 | 45.00 | |
| Z02_S01_E03 | C04_MURO_DE_CAMARA_SANITARIA | 0.40 | 0.932 | 1.049 | 4.00 | 4.00 | 270.00 | 90.00 | W |
| Z02_S01_E04 | C04_MURO_DE_CAMARA_SANITARIA | 0.40 | 0.932 | 1.049 | 4.00 | 4.00 | 180.00 | 90.00 | S |
| Z02_S01_E05 | C04_MURO_DE_CAMARA_SANITARIA | 0.40 | 0.932 | 1.049 | 4.00 | 4.00 | 0.00 | 90.00 | N |
| Z02_S01_E06 | C04_MURO_DE_CAMARA_SANITARIA | 0.40 | 0.932 | 1.049 | 4.00 | 4.00 | 90.00 | 90.00 | E |
| Z02_S01_E01 | C06_SOLERA_DE_CAMARA_SANITAR (INV) | 0.40 | 0.599 | 0.663 | 64.00 | 64.00 | 90.00 | 180.00 |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| Z01_S01_E01 | C03_FORJADO_INTERIOR (INV) | 0.40 | 0.364 | 0.404 | 64.00 | 64.00 | 90.00 | 180.00 | |
| Z01_S02_E01 | C02_FORJADO_CON_CAMARA_SANIT (INV) | 0.40 | 0.219 | 0.233 | 64.00 | 64.00 | 90.00 | 180.00 | |
| iz-Z01_S01_E01 | iz-C03_FORJADO_INTERIOR (INV) | 0.40 | 0.364 | 0.404 | 64.00 | 64.00 | 270.00 | 0.00 | |
| iz-Z01_S02_E01 | iz-C02_FORJADO_CON_CAMARA_SANIT (INV) | 0.40 | 0.219 | 0.233 | 64.00 | 64.00 | 270.00 | 0.00 | |
| Z01_VIVIENDA FURNITURE | FURNIT_INTERNALMASS | 0.40 | 3.600 | 64.00 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| Z01_S01_E07_G1 | H04_WINDOW | R08_VENTANA_P03_SUR_Y_ESTE (63MM) | 1.20 | 0.30 | 0.00 | 1.50 | 1.50 | 0.999 | 0.421 | 0.336 | 4.054 | 0.000 | CurtainWall | 1.207 | 0.376 | 0.295 | Yes | Z01_S01_E07 | 180.00 | 90.00 | S |
| Z01_S01_E08_G1 | H05_WINDOW | R07_VENTANA_P03_NORTE (63MM) | 1.20 | 0.30 | 0.00 | 1.50 | 1.50 | 0.999 | 0.611 | 0.537 | 4.054 | 0.000 | CurtainWall | 1.207 | 0.542 | 0.471 | Yes | Z01_S01_E08 | 0.00 | 90.00 | N |
| Z01_S01_E09_G1 | H04_WINDOW | R08_VENTANA_P03_SUR_Y_ESTE (63MM) | 1.20 | 0.30 | 0.00 | 1.50 | 1.50 | 0.999 | 0.421 | 0.336 | 4.054 | 0.000 | CurtainWall | 1.207 | 0.376 | 0.295 | Yes | Z01_S01_E09 | 90.00 | 90.00 | E |
| Z01_S01_E09_G2 | H04_WINDOW | R08_VENTANA_P03_SUR_Y_ESTE (63MM) | 1.20 | 0.30 | 0.00 | 1.50 | 1.50 | 0.999 | 0.421 | 0.336 | 4.054 | 0.000 | CurtainWall | 1.207 | 0.376 | 0.295 | Yes | Z01_S01_E09 | 90.00 | 90.00 | E |
| Z01_S02_E03_G2 | H06_WINDOW | R05_VENTANA_P02_OESTE (91MM) | 1.65 | 0.55 | 0.00 | 2.20 | 2.20 | 0.999 | 0.421 | 0.336 | 2.013 | 0.000 | CurtainWall | 1.119 | 0.354 | 0.277 | Yes | Z01_S02_E03 | 270.00 | 90.00 | W |
| Z01_S02_E04_G1 | H07_WINDOW | R06_VENTANA_P02_SUR (202MM) | 8.25 | 2.75 | 0.00 | 11.00 | 11.00 | 0.999 | 0.421 | 0.336 | 2.013 | 0.000 | CurtainWall | 1.216 | 0.278 | 0.214 | Yes | Z01_S02_E04 | 180.00 | 90.00 | S |
| Z01_S02_E05_G1 | H08_WINDOW | R04_VENTANA_P02_NORTE_Y_ESTE (170MM) | 4.95 | 1.65 | 0.00 | 6.60 | 6.60 | 0.999 | 0.611 | 0.537 | 2.013 | 0.000 | CurtainWall | 1.189 | 0.429 | 0.370 | Yes | Z01_S02_E05 | 0.00 | 90.00 | N |
| Z01_S02_E06_G1 | H08_WINDOW | R04_VENTANA_P02_NORTE_Y_ESTE (170MM) | 4.95 | 1.65 | 0.00 | 6.60 | 6.60 | 0.999 | 0.611 | 0.537 | 2.013 | 0.000 | CurtainWall | 1.189 | 0.429 | 0.370 | Yes | Z01_S02_E06 | 90.00 | 90.00 | E |
| Z01_S01_E02_G1 | H02_SKYLIGHT | R01_LUCERNARIO_NORTE (53MM) | 0.80 | 0.20 | 0.00 | 1.00 | 1.00 | 0.999 | 0.611 | 0.537 | 4.054 | 0.000 | CurtainWall | 1.180 | 0.555 | 0.481 | Yes | Z01_S01_E02 | 0.00 | 45.00 | |
| Z01_S01_E03_G1 | H03_SKYLIGHT | R02_LUCERNARIO_SUR_Y_ESTE (53MM) | 0.80 | 0.20 | 0.00 | 1.00 | 1.00 | 0.999 | 0.421 | 0.336 | 4.054 | 0.000 | CurtainWall | 1.180 | 0.385 | 0.301 | Yes | Z01_S01_E03 | 90.00 | 45.00 | |
| Z01_S01_E03_G2 | H03_SKYLIGHT | R02_LUCERNARIO_SUR_Y_ESTE (53MM) | 0.80 | 0.20 | 0.00 | 1.00 | 1.00 | 0.999 | 0.421 | 0.336 | 4.054 | 0.000 | CurtainWall | 1.180 | 0.385 | 0.301 | Yes | Z01_S01_E03 | 90.00 | 45.00 | |
| Z01_S01_E04_G1 | H03_SKYLIGHT | R02_LUCERNARIO_SUR_Y_ESTE (53MM) | 0.80 | 0.20 | 0.00 | 1.00 | 1.00 | 0.999 | 0.421 | 0.336 | 4.054 | 0.000 | CurtainWall | 1.180 | 0.385 | 0.301 | Yes | Z01_S01_E04 | 180.00 | 45.00 | |
| Total or Average | 36.40 | 0.999 | 0.503 | 0.422 | |||||||||||||||||
| North Total or Average | 8.10 | 0.999 | 0.611 | 0.537 | |||||||||||||||||
| Non-North Total or Average | 28.30 | 0.999 | 0.472 | 0.390 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| H04_WINDOW:WSC_MAT_1:INT | R08_VENTANA_P03_SUR_Y_ESTE (63MM) | 0.815 | 0.411 | 0.278 | CurtainWall | 1.045 | 0.069 | 0.244 |
| H05_WINDOW:WSC_MAT_1:INT | R07_VENTANA_P03_NORTE (63MM) | 0.815 | 0.602 | 0.421 | CurtainWall | 1.045 | 0.061 | 0.370 |
| H06_WINDOW:WSC_MAT_1:INT | R05_VENTANA_P02_OESTE (91MM) | 0.815 | 0.411 | 0.278 | CurtainWall | 0.966 | 0.065 | 0.230 |
| H07_WINDOW:WSC_MAT_1:INT | R06_VENTANA_P02_SUR (202MM) | 0.815 | 0.411 | 0.278 | CurtainWall | 1.097 | 0.055 | 0.177 |
| H08_WINDOW:WSC_MAT_1:INT | R04_VENTANA_P02_NORTE_Y_ESTE (170MM) | 0.815 | 0.602 | 0.421 | CurtainWall | 1.061 | 0.051 | 0.290 |
| H02_SKYLIGHT:WSC_MAT_1:INT | R01_LUCERNARIO_NORTE (53MM) | 0.815 | 0.602 | 0.421 | CurtainWall | 1.014 | 0.063 | 0.378 |
| H03_SKYLIGHT:WSC_MAT_1:INT | R02_LUCERNARIO_SUR_Y_ESTE (53MM) | 0.815 | 0.411 | 0.278 | CurtainWall | 1.014 | 0.072 | 0.249 |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| Z01_S02_E03_G1 | H01_DOOR | 2.303 | 3.514 | 2.20 | Z01_S02_E03 |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| Z01_S01_E07_G1 | 0.90 | 0.97 | 0.96 | 0.00 | 0.91 | 0.89 | 0.96 | 0.98 | 0.98 |
| Z01_S01_E08_G1 | 0.00 | 0.00 | 0.00 | 0.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Z01_S01_E09_G1 | 0.99 | 0.92 | 0.00 | 0.99 | 0.92 | 0.00 | 0.98 | 0.89 | 0.00 |
| Z01_S01_E09_G2 | 0.99 | 0.92 | 0.00 | 0.99 | 0.92 | 0.00 | 0.98 | 0.89 | 0.00 |
| Z01_S02_E03_G2 | 0.00 | 0.00 | 0.03 | 0.00 | 0.00 | 0.31 | 0.00 | 0.00 | 0.00 |
| Z01_S02_E04_G1 | 0.01 | 0.14 | 0.14 | 0.00 | 0.00 | 0.00 | 0.49 | 0.55 | 0.54 |
| Z01_S02_E05_G1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Z01_S02_E06_G1 | 0.87 | 0.37 | 0.00 | 0.82 | 0.20 | 0.00 | 0.86 | 0.29 | 0.00 |
| Z01_S01_E02_G1 | 0.00 | 0.00 | 0.00 | 0.92 | 0.93 | 0.93 | 0.00 | 0.00 | 0.00 |
| Z01_S01_E03_G1 | 0.97 | 0.97 | 0.80 | 0.99 | 0.98 | 0.91 | 0.95 | 0.95 | 0.00 |
| Z01_S01_E03_G2 | 0.97 | 0.97 | 0.80 | 0.99 | 0.98 | 0.91 | 0.95 | 0.95 | 0.00 |
| Z01_S01_E04_G1 | 0.93 | 0.99 | 0.99 | 0.91 | 0.97 | 0.97 | 0.93 | 0.98 | 0.98 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| Z01_S01_E07_G1 | WSC_CTRL_1_1 | Interior Shade | H04_WINDOW:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S01_E08_G1 | WSC_CTRL_1_1 | Interior Shade | H05_WINDOW:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S01_E09_G1 | WSC_CTRL_1_1 | Interior Shade | H04_WINDOW:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S01_E09_G2 | WSC_CTRL_1_1 | Interior Shade | H04_WINDOW:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S02_E03_G2 | WSC_CTRL_1_1 | Interior Shade | H06_WINDOW:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S02_E04_G1 | WSC_CTRL_1_1 | Interior Shade | H07_WINDOW:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S02_E05_G1 | WSC_CTRL_1_1 | Interior Shade | H08_WINDOW:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S02_E06_G1 | WSC_CTRL_1_1 | Interior Shade | H08_WINDOW:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S01_E02_G1 | WSC_CTRL_1_1 | Interior Shade | H02_SKYLIGHT:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S01_E03_G1 | WSC_CTRL_1_1 | Interior Shade | H03_SKYLIGHT:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S01_E03_G2 | WSC_CTRL_1_1 | Interior Shade | H03_SKYLIGHT:WSC_MAT_1:INT | AlwaysOff | No |
| Z01_S01_E04_G1 | WSC_CTRL_1_1 | Interior Shade | H03_SKYLIGHT:WSC_MAT_1:INT | AlwaysOff | No |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [kWh] | |
| Z01_VIVIENDA_IG2 LIGHTS | Z01_VIVIENDA | Z01_VIVIENDA | GENERAL | 4.4000 | 128.00 | 563.20 | 1 | SCHED6 | 63.00 | 168.00 | 63.00 | 0.0000 | Y | 1850.10 |
| Interior Lighting Total | 4.4000 | 128.00 | 563.20 | 1850.10 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| None |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [kWh] | |
| Exterior Lighting Total | 0.00 | 0.00 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| EQ1_SYSTEM1_CALDERA_DE_BIOMASA | Boiler:HotWater | 25000.00 | 0.93 |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| None |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| None |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP2 [W/W] | EER2 [Btu/W-h] | SEER2 User [Btu/W-h] | SEER2 Standard [Btu/W-h] | IEER2 [Btu/W-h] | |
| None |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| None |
| Coil Type | Rated Total Capacity [W] | Rated Sensible Capacity [W] | Rated Power[W] | Rated COP [W/W] | Rated Air Dry-bulb Temperature [C] | Rated Air Wet-bulb Temperature [C] | Rated Water Temperature [C] | Design Day used for Sizing | |
| None |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| None |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF2 [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| None |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| None |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| LOOP_HW1_SYSTEM1_SISTEMA_MIXTO_CALEFACCION SUPPLY PUMP | Pump:ConstantSpeed | Intermittent | 0.00 | 0.000482 | 0.00 | 0.00 | 0.90 | General |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| None |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| Z01_VIVIENDA | 1739.42 | 1739.42 | 13.59 | 0.122 | 0.122 | SUMMER | 9/4 16:00:00 | 25.00 | 25.00 | 0.00818 | 31.30 | 0.00767 | 0.000 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| Z01_VIVIENDA | 4509.97 | 4509.97 | 35.23 | 0.131 | 0.131 | WINTER | 1/12 08:00:00 | 20.00 | 20.00 | 0.00352 | -4.40 | 0.00240 | 0.000 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| None |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| None |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| None |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| None |
Report: System Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| None |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| None |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| Z01_VIVIENDA | 6215.50 | 7793.50 | 5546.50 |
| Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 0.00 |
| Facility | 6215.50 | 7793.50 | 5546.50 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| Z01_VIVIENDA | 0.00 | 233.50 | 0.00 | 233.50 |
| Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 233.50 | 0.00 | 233.50 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| Z01_VIVIENDA | 3.11 | 4.49 | 341.52 | 0.000 | 0.000 | 0.000 | 0.000 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| Z01_VIVIENDA | 3.11 | 4.49 | 341.52 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| Z01_VIVIENDA | 3.11 | 4.49 | 341.52 | 128.00 | 0.000 | ||
| Total Facility | 3.11 | 4.49 | 341.52 | 128.00 | 0.0000 | 0.000 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| Z01_VIVIENDA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| Z01_VIVIENDA | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.00 | 0.00 | 0.00 |
| Total Facility | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.00 | 0.00 | 0.00 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| None |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| None |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| None |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| None |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Surfaces by Class| Total | Outdoors | |
| Wall | 16 | 16 |
| Floor | 3 | 1 |
| Roof | 6 | 4 |
| Internal Mass | 1 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 12 | 12 |
| Door | 1 | 1 |
| Glass Door | 0 | 0 |
| Shading | 6 | 6 |
| Overhang | 1 | 1 |
| Fin | 1 | 1 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 0 |
| Conditioned Zones | 1 |
| Unconditioned Zones | 1 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 371 |
| Defaulted Fields | 153 |
| Fields with Defaults | 804 |
| Autosized Fields | 7 |
| Autosizable Fields | 10 |
| Autocalculated Fields | 1 |
| Autocalculatable Fields | 80 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Annual and Peak Values - Electricity| Electricity Annual Value [kWh] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 3760.79 | 112.64 | 31-MAY-23:15 | 1134.18 | 01-JAN-19:15 |
| Electricity:Building | 3760.79 | 112.64 | 31-MAY-23:15 | 1134.18 | 01-JAN-19:15 |
| Electricity:Zone:Z01_VIVIENDA | 3760.79 | 112.64 | 31-MAY-23:15 | 1134.18 | 01-JAN-19:15 |
| Electricity:SpaceType:GENERAL | 3700.23 | 112.64 | 01-JAN-00:15 | 1126.40 | 01-JAN-19:15 |
| InteriorLights:Electricity | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| InteriorLights:Electricity:Zone:Z01_VIVIENDA | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| InteriorLights:Electricity:SpaceType:GENERAL | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| 1:InteriorLights:Electricity | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| 1:InteriorLights:Electricity:Zone:Z01_VIVIENDA | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| 1:InteriorLights:Electricity:SpaceType:GENERAL | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| InteriorEquipment:Electricity | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| InteriorEquipment:Electricity:Zone:Z01_VIVIENDA | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| InteriorEquipment:Electricity:SpaceType:GENERAL | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| General:InteriorEquipment:Electricity | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| General:InteriorEquipment:Electricity:Zone:Z01_VIVIENDA | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| General:InteriorEquipment:Electricity:SpaceType:GENERAL | 1850.11 | 56.32 | 01-JAN-00:15 | 563.20 | 01-JAN-19:15 |
| Fans:Electricity | 60.56 | 0.00 | 31-MAY-23:15 | 7.78 | 24-NOV-01:45 |
| Fans:Electricity:Zone:Z01_VIVIENDA | 60.56 | 0.00 | 31-MAY-23:15 | 7.78 | 24-NOV-01:45 |
| Ventilation (simple):Fans:Electricity | 60.56 | 0.00 | 31-MAY-23:15 | 7.78 | 24-NOV-01:45 |
| Ventilation (simple):Fans:Electricity:Zone:Z01_VIVIENDA | 60.56 | 0.00 | 31-MAY-23:15 | 7.78 | 24-NOV-01:45 |
| ElectricityPurchased:Facility | 3760.78 | 112.64 | 31-MAY-23:30 | 1134.18 | 01-JAN-19:15 |
| ElectricityPurchased:Plant | 3760.78 | 112.64 | 31-MAY-23:30 | 1134.18 | 01-JAN-19:15 |
| Cogeneration:ElectricityPurchased | 3760.78 | 112.64 | 31-MAY-23:30 | 1134.18 | 01-JAN-19:15 |
| General:Cogeneration:ElectricityPurchased | 3760.78 | 112.64 | 31-MAY-23:30 | 1134.18 | 01-JAN-19:15 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| ElectricityNet:Facility | 3760.78 | 112.64 | 31-MAY-23:30 | 1134.18 | 01-JAN-19:15 |
| ElectricityNet:Plant | 3760.78 | 112.64 | 31-MAY-23:30 | 1134.18 | 01-JAN-19:15 |
| Cogeneration:ElectricityNet | 3760.78 | 112.64 | 31-MAY-23:30 | 1134.18 | 01-JAN-19:15 |
| General:Cogeneration:ElectricityNet | 3760.78 | 112.64 | 31-MAY-23:30 | 1134.18 | 01-JAN-19:15 |
| Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| Pumps:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| General:Pumps:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| Natural Gas Annual Value [kWh] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Cooling Annual Value [kWh] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 40.87 | 0.00 | 02-JAN-07:15 | 0.00 | 01-JAN-07:15 |
| Water:Plant | 40.87 | 0.00 | 02-JAN-07:15 | 0.00 | 01-JAN-07:15 |
| WaterSystems:Water | 40.87 | 0.00 | 02-JAN-07:15 | 0.00 | 01-JAN-07:15 |
| General:WaterSystems:Water | 40.87 | 0.00 | 02-JAN-07:15 | 0.00 | 01-JAN-07:15 |
| MainsWater:Facility | 40.87 | 0.00 | 02-JAN-07:15 | 0.00 | 01-JAN-07:15 |
| MainsWater:Plant | 40.87 | 0.00 | 02-JAN-07:15 | 0.00 | 01-JAN-07:15 |
| WaterSystems:MainsWater | 40.87 | 0.00 | 02-JAN-07:15 | 0.00 | 01-JAN-07:15 |
| General:WaterSystems:MainsWater | 40.87 | 0.00 | 02-JAN-07:15 | 0.00 | 01-JAN-07:15 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| CO2:Facility | 1977.17 | 0.000 | 03-JUL-23:30 | 0.000 | 15-JAN-21:00 |
| ElectricityEmissions:CO2 | 1244.82 | 0.000 | 31-MAY-23:30 | 0.000 | 01-JAN-19:15 |
| CO:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:CO | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CH4:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:CH4 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NOx:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:NOx | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| N2O:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:N2O | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| SO2:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:SO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PM:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:PM | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PM10:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:PM10 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PM2.5:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:PM2.5 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NH3:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:NH3 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NMVOC:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:NMVOC | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| Hg:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:Hg | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| Pb:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:Pb | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| Nuclear High:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:Nuclear High | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:CO2 | 652.76 | 0.000 | 05-JUL-23:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:CO | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:CH4 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:NOx | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:N2O | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:SO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:PM | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:PM10 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:PM2.5 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:NH3 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:NMVOC | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:Hg | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:Pb | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:Nuclear High | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:CO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:CO | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:CH4 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:NOx | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:N2O | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:SO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:PM | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:PM10 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:PM2.5 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:NH3 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:NMVOC | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:Hg | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:Pb | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:Nuclear High | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:CO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:CO | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:CH4 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:NOx | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:N2O | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:SO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:PM | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:PM10 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:PM2.5 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:NH3 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:NMVOC | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:Hg | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:Pb | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:Nuclear High | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:CO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:CO | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:CH4 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:NOx | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:N2O | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:SO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:PM | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:PM10 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:PM2.5 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:NH3 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:NMVOC | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:Hg | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:Pb | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:Nuclear High | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:CO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:CO | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:CH4 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:NOx | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:N2O | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:SO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:PM | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:PM10 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:PM2.5 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:NH3 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:NMVOC | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:Hg | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:Pb | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:Nuclear High | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:CO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:CO | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:CH4 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:NOx | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:N2O | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:SO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:PM | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:PM10 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:PM2.5 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:NH3 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:NMVOC | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:Hg | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:Pb | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:Nuclear High | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:CO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:CO | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:CH4 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:NOx | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:N2O | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:SO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:PM | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:PM10 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:PM2.5 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:NH3 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:NMVOC | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:Hg | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:Pb | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:Nuclear High | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:CO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:CO | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:CH4 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:NOx | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:N2O | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:SO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:PM | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:PM10 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:PM2.5 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:NH3 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:NMVOC | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:Hg | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:Pb | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:Nuclear High | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:CO2 | 79.60 | 0.000 | 01-JAN-00:15 | 0.000 | 27-DEC-07:15 |
| OtherFuel2Emissions:CO | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:CH4 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:NOx | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:N2O | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:SO2 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:PM | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:PM10 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:PM2.5 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:NH3 | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:NMVOC | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:Hg | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:Pb | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:Nuclear High | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| Carbon Equivalent:Facility | 539.17 | 0.000 | 03-JUL-23:30 | 0.000 | 15-JAN-21:00 |
| CarbonEquivalentEmissions:Carbon Equivalent | 539.17 | 0.000 | 03-JUL-23:30 | 0.000 | 15-JAN-21:00 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Nuclear Low:Facility | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:Nuclear Low | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:Nuclear Low | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:Nuclear Low | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:Nuclear Low | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:Nuclear Low | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:Nuclear Low | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:Nuclear Low | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:Nuclear Low | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:Nuclear Low | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:Nuclear Low | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| WaterEnvironmentalFactors:Facility | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| ElectricityEmissions:WaterEnvironmentalFactors | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| NaturalGasEmissions:WaterEnvironmentalFactors | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| PropaneEmissions:WaterEnvironmentalFactors | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo1Emissions:WaterEnvironmentalFactors | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| FuelOilNo2Emissions:WaterEnvironmentalFactors | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| CoalEmissions:WaterEnvironmentalFactors | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| DieselEmissions:WaterEnvironmentalFactors | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| GasolineEmissions:WaterEnvironmentalFactors | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel1Emissions:WaterEnvironmentalFactors | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| OtherFuel2Emissions:WaterEnvironmentalFactors | 0.000 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
| Annual Value [kWh] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 12337.32 | 0.00 | 01-JAN-00:15 | 17644.65 | 27-DEC-07:15 |
| EnergyTransfer:Building | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| EnergyTransfer:Zone:Z01_VIVIENDA | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| Heating:EnergyTransfer | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| Heating:EnergyTransfer:Zone:Z01_VIVIENDA | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| General:Heating:EnergyTransfer | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| General:Heating:EnergyTransfer:Zone:Z01_VIVIENDA | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| Cooling:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| Cooling:EnergyTransfer:Zone:Z01_VIVIENDA | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| General:Cooling:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| General:Cooling:EnergyTransfer:Zone:Z01_VIVIENDA | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| EnergyTransfer:Zone:Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| Heating:EnergyTransfer:Zone:Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| General:Heating:EnergyTransfer:Zone:Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| Cooling:EnergyTransfer:Zone:Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| General:Cooling:EnergyTransfer:Zone:Z02_CAMARA_SANITARIA | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| DistrictHeating:Facility | 2383.08 | 232.62 | 03-JUL-23:30 | 302.72 | 01-JAN-00:15 |
| DistrictHeating:Plant | 2383.08 | 232.62 | 03-JUL-23:30 | 302.72 | 01-JAN-00:15 |
| WaterSystems:DistrictHeating | 2383.08 | 232.62 | 03-JUL-23:30 | 302.72 | 01-JAN-00:15 |
| General:WaterSystems:DistrictHeating | 2383.08 | 232.62 | 03-JUL-23:30 | 302.72 | 01-JAN-00:15 |
| EnergyTransfer:HVAC | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| Baseboard:EnergyTransfer | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| PlantLoopHeatingDemand:Facility | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| PlantLoopHeatingDemand:HVAC | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| Baseboard:PlantLoopHeatingDemand | 4112.45 | 0.00 | 01-JAN-00:15 | 5957.89 | 27-DEC-07:15 |
| EnergyTransfer:Plant | 4112.43 | 0.00 | 01-JAN-00:15 | 5728.87 | 27-DEC-07:15 |
| Boilers:EnergyTransfer | 4112.43 | 0.00 | 01-JAN-00:15 | 5728.87 | 27-DEC-07:15 |
| OtherFuel2:Facility | 4421.97 | 0.00 | 01-JAN-00:15 | 6160.08 | 27-DEC-07:15 |
| OtherFuel2:Plant | 4421.97 | 0.00 | 01-JAN-00:15 | 6160.08 | 27-DEC-07:15 |
| Heating:OtherFuel2 | 4421.97 | 0.00 | 01-JAN-00:15 | 6160.08 | 27-DEC-07:15 |
| Boiler:Heating:OtherFuel2 | 4421.97 | 0.00 | 01-JAN-00:15 | 6160.08 | 27-DEC-07:15 |
| Source:Facility | 22732.73 | 533.46 | 12-JUN-23:30 | 8772.17 | 15-JAN-21:00 |
| ElectricityEmissions:Source | 8905.54 | 266.73 | 12-JUN-23:30 | 2685.74 | 01-JAN-19:15 |
| PurchasedElectricityEmissions:Source | 8905.54 | 266.73 | 12-JUN-23:30 | 2685.74 | 01-JAN-19:15 |
| SoldElectricityEmissions:Source | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| NaturalGasEmissions:Source | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| PropaneEmissions:Source | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| FuelOilNo1Emissions:Source | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| FuelOilNo2Emissions:Source | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| CoalEmissions:Source | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| DieselEmissions:Source | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| GasolineEmissions:Source | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| OtherFuel1Emissions:Source | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
| OtherFuel2Emissions:Source | 4921.65 | 0.00 | 01-JAN-00:15 | 6856.17 | 27-DEC-07:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [kWh] | HVAC Zone Eq & Other Sensible Air Cooling [kWh] | HVAC Terminal Unit Sensible Air Heating [kWh] | HVAC Terminal Unit Sensible Air Cooling [kWh] | HVAC Input Heated Surface Heating [kWh] | HVAC Input Cooled Surface Cooling [kWh] | People Sensible Heat Addition [kWh] | Lights Sensible Heat Addition [kWh] | Equipment Sensible Heat Addition [kWh] | Window Heat Addition [kWh] | Interzone Air Transfer Heat Addition [kWh] | Infiltration Heat Addition [kWh] | Opaque Surface Conduction and Other Heat Addition [kWh] | Equipment Sensible Heat Removal [kWh] | Window Heat Removal [kWh] | Interzone Air Transfer Heat Removal [kWh] | Infiltration Heat Removal [kWh] | Opaque Surface Conduction and Other Heat Removal [kWh] | |
| Z01_VIVIENDA | 4112.447 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1693.764 | 1850.113 | 1850.113 | 5671.272 | 0.000 | 26.219 | 0.087 | 0.000 | -1681.16 | 0.000 | -7084.19 | -6438.58 |
| Z02_CAMARA_SANITARIA | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
| Total Facility | 4112.447 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1693.764 | 1850.113 | 1850.113 | 5671.272 | 0.000 | 26.219 | 0.087 | 0.000 | -1681.16 | 0.000 | -7084.19 | -6438.58 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| Z01_VIVIENDA | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Z02_CAMARA_SANITARIA | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| Z01_VIVIENDA | 25-NOV-07:15 | 10806.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 275.41 | 168.96 | 168.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -395.21 | 0.00 | -864.97 | -10159.60 |
| Z02_CAMARA_SANITARIA | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 25-NOV-07:15 | 10806.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 275.41 | 168.96 | 168.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -395.21 | 0.00 | -864.97 | -10159.60 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| None |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| None |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| None |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| None |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| None |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| None |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| None |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Sec1.1A-General Information| Data | |
| Weather File | RUNPERIOD 1 ** E1_peninsula - ESP CTE_DB_HE WMO#= |
| Total gross floor area [m2] | 192.00 |
| Principal Heating Source | Additional Fuel |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| Z01_VIVIENDA | 128.00 | 128.00 | 0.00 | 168.00 |
| Z02_CAMARA_SANITARIA | 64.00 | 0.00 | 64.00 | 0.00 |
| Totals | 192.00 | 128.00 | 64.00 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 233.50 |
| Number of hours not met | 233.50 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [kWh] | Electricity Demand [W] | Natural Gas Energy Use [kWh] | Natural Gas Demand [W] | Gasoline Use [kWh] | Gasoline Demand [W] | Diesel Use [kWh] | Diesel Demand [W] | Coal Use [kWh] | Coal Demand [W] | Fuel Oil No 1 Use [kWh] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [kWh] | Fuel Oil No 2 Demand [W] | Propane Use [kWh] | Propane Demand [W] | Other Fuel 1 Use [kWh] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [kWh] | Other Fuel 2 Demand [W] | District Cooling Use [kWh] | District Cooling Demand [W] | District Heating Use [kWh] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heating -- Boiler | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4421.97 | 6160.08 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heating -- Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- 1 | 1850.11 | 563.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- General | 1850.11 | 563.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- Ventilation (simple) | 60.56 | 7.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2383.08 | 302.72 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [kWh] | Total Energy Use [kWh] | |
| Electricity | 1850.11 | 3760.79 |
| Natural Gas | 0.00 | 0.00 |
| Additional | 0.00 | 6805.05 |
| Total | 1850.11 | 10565.83 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [kWh] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [kWh/m2] | |
| Interior Lighting (All) | 9.64 |
| Space Heating | 0.00 |
| Space Cooling | 0.00 |
| Fans (All) | 0.32 |
| Service Water Heating | 0.00 |
| Receptacle Equipment | 9.64 |
| Miscellaneous (All) | 19.59 |
| Subtotal | 19.59 |
| Natural Gas [kWh/m2] | |
| Space Heating | 0.00 |
| Service Water Heating | 0.00 |
| Miscellaneous (All) | 0.00 |
| Subtotal | 0.00 |
| Additional [kWh/m2] | |
| Subtotal | 23.03 |
| Miscellaneous | 23.03 |
| Percent [%] | |
| Interior Lighting (All) | 17.51 |
| Space Heating | 41.85 |
| Space Cooling | 0.00 |
| Fans (All) | 0.57 |
| Service Water Heating | 22.55 |
| Receptacle Equipment | 17.51 |
| Miscellaneous | 0.00 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| SCHED2_FLOW_RATE_FRACTION | 8760. | 8760. |
| SCHED4_ACC_RESID | 3896. | 3896. |
| SCHED5 | 6150. | 8760. |
| SCHED6 | 3285. | 8760. |
| SCHED7 | 7784. | 7784. |
| SCHED8 | 976. | 976. |
| WORK EFF SCH | 0. | 0. |
| CLOTHING SCH | 8760. | 8760. |
| AIR VELO SCH | 1200. | 8760. |
| SUMMERNIGHTVENTILATION SCH | 976. | 976. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| SCHED0_CTE | THERMOSTAT_Z01_VIVIENDA SETPOINT | January | 20.00 | 246 | 20.00 | 246 |
| SCHED1_CTE | THERMOSTAT_Z01_VIVIENDA SETPOINT | July | 100.00 | 365 | 27.00 | 119 |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2026-07-16 13:48:06
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| None |